Monofocal intraocular lenses

SENSARTM Monofocal 1-Piece IOL AAB00

1-Piece spheric lens with ProTec edge design. 360° posterior square edges to reduce epithelial cell migration1,2

  •  Insertion with:
    • UNFOLDERTM Platinum 1-Series Handpiece, model DK7796 – Cartridge: 1MTEC30
    • UNFOLDERTM Platinum Push Inserter, model DK7798 (only up to 28 D) – Cartridge: 1VTEC30
  • Range available: From 6.0 D to 30.0 D in 0.5 D increments
  • Lens diameter/overall length: 6.0/13.0 mm
  • Edge design: ProTec frosted continuous 360° posterior square edge
  • Material: Soft foldable hydrophobic acrylic with a covalently bound UV absorber
  • A-Constant optical/ultrasound3: Not specified/118.4*
  • Theoretical anterior chamber depth (ACD) (optical/ultrasound): 5.2 mm
  • Refractive index: 1.47 at 35°C
  • Haptics: Hydrophobic acrylic
  • Haptic design: Haptics offset from optic, Tri-Fix design

*Value theoretically derived for a typical 20.00 D lens. Johnson & Johnson recommends that surgeons personalize their A-constant based on their surgical techniques and equipment, experience with the lens model and postoperative results.

  1. SENSARTM 1-Piece IOL DfU – INT – Z311587, current revision.
  2. Nixon DR, Woodcock MG. Pattern of posterior capsule opacification models 2 years postoperatively with 2 single-piece acrylic intraocular lenses. J Cataract Refract Surg 2010;36(6):929-934. REF20140020.
  3. Holladay JT. International Intraocular Lens & Implant Registry 2003. J Cataract Refract Surg. 2003; 29:176-197. REF2016CT0151.

Monofocal intraocular lenses

SENSARTM 1-Piece IOL AAB00

1-Piece spheric lens with ProTec edge design. 360° posterior square edges to reduce epithelial cell migration1,2

  •  Insertion with:
    • UNFOLDERTM Platinum 1-Series Handpiece, model DK7796 – Cartridge: 1MTEC30
    • UNFOLDERTM Platinum Push Inserter, model DK7798 (only up to 28 D) – Cartridge: 1VTEC30
  • Range available: From 6.0 D to 30.0 D in 0.5 D increments
  • Lens diameter/overall length: 6.0/13.0 mm
  • Edge design: ProTec frosted continuous 360° posterior square edge
  • Material: Soft foldable hydrophobic acrylic with a covalently bound UV absorber
  • A-Constant optical/ultrasound3: Not specified/118.4*
  • Theoretical anterior chamber depth (ACD) (optical/ultrasound): 5.2 mm
  • Refractive index: 1.47 at 35°C
  • Haptics: Hydrophobic acrylic
  • Haptic design: Haptics offset from optic, Tri-Fix design

 

*Value theoretically derived for a typical 20.00 D lens. Johnson & Johnson Vision recommends that surgeons personalize their A-constant based on their surgical techniques and equipment, experience with the lens model and postoperative results.

 

  1. SENSARTM 1-Piece IOL DfU – INT – Z311129, Rev. C, 09/2019. REF2021OTH4865.
  2. Nixon DR, Woodcock MG. Pattern of posterior capsule opacification models 2 years postoperatively with 2 single-piece acrylic intraocular lenses. J Cataract Refract Surg 2010;36(6):929-934. REF20140020.
  3. Holladay JT. International Intraocular Lens & Implant Registry 2003. J Cataract Refract Surg. 2003; 29:176-197. REF2016CT0151.

For healthcare professionals only. Please reference the Instructions for Use for a complete list of Indications and Important Safety Information and contact our specialists in case of any question. 
© Johnson & Johnson and its affiliates 2024. 2024PP10236