Gentle docking procedure with less intraocular pressure rise2, allowing for a broad inclusion criteria.
LIQUID OPTICSTM Interface consists of suction ring, disposable lens, and fluid catchment.
Offered in two sizes to give you the flexibility to choose the interface that is optimal for each patient.
• LIQUID OPTICSTM Interface
– Diameter (outer/inner): 21.6 / 14.1 mm
• LIQUID OPTICSTM Interface 12
– Diameter (outer/inner): 19 / 12 mm
• LOI-12 Ordering #: LOI-12
• LOI-14 Ordering #: LOI
• GEN2-12 Ordering #: 0180 – 1201
• GEN2-14 Ordering #: 0180 – 1401
• Daily Alignment Verification Pack (50) Ordering #: SA-08044
Type: 3D spectral domain
Wavelength: 820 – 930 nm
Resolution: axial = 30 μm; lateral = 15 μm
Streaming: 0.5 – 2 Hz
Docking: Guided with vacuum footswitch and docking keypad
User interface: 61 cm (24 inch), high-definition touchscreen monitor
Patient chair: Configurable joystick for x, y, height adjustment
Laser: Footswitch
Type: Diode pumped solid-state
Pulse energy range: 1-10 μJ
Wavelength: 1030 nm (near infrared)
Pulse repetition rate: 120 kHz
Pulse duration: < 600 fs
Temperature: 15°C (59°F) to 32°C (90°F) – Temperature-controlled environment
Electrical: 200-240 V AC, Single Phase, 15 A
Weight: System: 340 kg (750 lbs); Patient chair: 172 kg (380 lbs)
Space required: 3.04 m (10’) x 3.35 m (11’) minimum required for system installation
1. CATALYSTM cOS 7.0 Op Manual OUS – 0160-6471, current revision.
2. Donaldson K, et al. Femtosecond laser-assisted cataract surgery. JCRS. 2013;39:1753-1763. REF2014CT0134.
Gentle docking procedure with less intraocular pressure rise2, allowing for a broad inclusion criteria.
LIQUID OPTICSTM Interface consists of suction ring, disposable lens, and fluid catchment.
Offered in two sizes to give you the flexibility to choose the interface that is optimal for each patient.
• LIQUID OPTICSTM Interface
– Diameter (outer/inner): 21.6 / 14.1 mm
• LIQUID OPTICSTM Interface 12
– Diameter (outer/inner): 19 / 12 mm
• LOI-12 Ordering #: LOI-12
• LOI-14 Ordering #: LOI
• GEN2-12 Ordering #: 0180 – 1201
• GEN2-14 Ordering #: 0180 – 1401
• Daily Alignment Verification Pack (50) Ordering #: SA-08044
Type: 3D spectral domain
Wavelength: 820 – 930 nm
Resolution: axial = 30 μm; lateral = 15 μm
Streaming: 0.5 – 2 Hz
Docking: Guided with vacuum footswitch and docking keypad
User interface: 61 cm (24 inch), high-definition touchscreen monitor
Patient chair: Configurable joystick for x, y, height adjustment
Laser: Footswitch
Type: Diode pumped solid-state
Pulse energy range: 1-10 μJ
Wavelength: 1030 nm (near infrared)
Pulse repetition rate: 120 kHz
Pulse duration: < 600 fs
Temperature: 15°C (59°F) to 32°C (90°F) – Temperature-controlled environment
Electrical: 200-240 V AC, Single Phase, 15 A
Weight: System: 340 kg (750 lbs); Patient chair: 172 kg (380 lbs)
Space required: 3.04 m (10’) x 3.35 m (11’) minimum required for system installation
1. CATALYSTM cOS6.0 Op Manual OUS – 0160-6413, Rev. D, July 2020. REF2021CT4168.
2. Donaldson K, et al. Femtosecond laser-assisted cataract surgery. JCRS. 2013;39:1753-1763. REF2014CT0134.
For Healthcare Professionals Only. Please reference the Instructions for Use for a complete list of Indications and Important Safety Information and contact our specialists in case of any question.
© Johnson & Johnson and its affiliates 2024. 2024PP10598