Monofocal intraocular lenses

TECNIS EyhanceTM IOL ICB00 (Preloaded DIB00)​​

1-Piece aspheric lens with ProTec edge design.

The wavefront of the aspheric anterior surface of the TECNISTM IOL optic is optimized so that the spherical aberration of the cornea is corrected to essentially zero.1,2

IOL provides improved intermediate vision.2,3

  •  Insertion with:
    • UNFOLDERTM Platinum 1-Series Handpiece, model DK7796 – Cartridge: 1MTEC30
    • UNFOLDERTM Platinum Push Inserter, model DK7798 (only up to 28 D) – Cartridge: 1VTEC30
  • Range available: From 5.0 D to 34.0 D in 0.5 D increments
  • Lens diameter/overall length: 6.0/13.0 mm
  • Edge design: ProTec frosted continuous 360° posterior square edge
  • Material: Soft foldable hydrophobic acrylic with a covalently bound UV absorber
  • A-Constant optical/ultrasound4:  119.3*/118.8†
  • Theoretical anterior chamber depth (ACD) (optical/ultrasound): 5.7/5.4 mm
  • Refractive index: 1.47 at 35°C
  • Haptics: Hydrophobic acrylic
  • Haptic design: Haptics offset from optic, Tri-Fix design

Also available preloaded in TECNIS SimplicityTM Delivery System.

*Value theoretically derived for a typical 20.00 D lens. Johnson & Johnson Vision recommends that surgeons personalize their A-constant based on their surgical techniques and equipment, experience with the lens model and postoperative results.

†Derived from clinical evaluation results of the TECNISTM 1-Piece Platform. 

  1. TECNIS™ 1-Piece IOL DfU – OUS – Doc #Z311252P, Rev C, Sep 2019. REF2019CT4495..
  2. TECNIS Eyhance IOL ICB00 – DfU INT – Z311058, Rev. 04, Dec. 2019. REF2020CT4318.

  3. DOF2018CT4015-Clinical investigation of the TECNIS Eyhance™ IOL, Model ICB00. Sep 2018 
  4. Holladay JT. International Intraocular Lens & Implant Registry 2003. J Cataract Refract Surg. 2003; 29:176-197. REF2016CT0151.

Monofocal intraocular lenses

TECNIS EyhanceTM IOL ICB00 (Preloaded DIB00)​​

1-Piece aspheric lens with ProTec edge design.

The wavefront of the aspheric anterior surface of the TECNISTM IOL optic is optimized so that the spherical aberration of the cornea is corrected to essentially zero.1,2

IOL provides improved intermediate vision.2,3

  •  Insertion with:
    • UNFOLDERTM Platinum 1-Series Handpiece, model DK7796 – Cartridge: 1MTEC30
    • UNFOLDERTM Platinum Push Inserter, model DK7798 (only up to 28 D) – Cartridge: 1VTEC30
  • Range available: From 5.0 D to 34.0 D in 0.5 D increments
  • Lens diameter/overall length: 6.0/13.0 mm
  • Edge design: ProTec frosted continuous 360° posterior square edge
  • Material: Soft foldable hydrophobic acrylic with a covalently bound UV absorber
  • A-Constant optical/ultrasound4:  119.3*/118.8†
  • Theoretical anterior chamber depth (ACD) (optical/ultrasound): 5.7/5.4 mm
  • Refractive index: 1.47 at 35°C
  • Haptics: Hydrophobic acrylic
  • Haptic design: Haptics offset from optic, Tri-Fix design

Also available preloaded in TECNIS SimplicityTM Delivery System.

*Value theoretically derived for a typical 20.00 D lens. Johnson & Johnson Vision recommends that surgeons personalize their A-constant based on their surgical techniques and equipment, experience with the lens model and postoperative results.

†Derived from clinical evaluation results of the TECNISTM 1-Piece Platform. 

  1. TECNIS™ 1-Piece IOL DfU – OUS – Doc #Z311252P, Rev C, Sep 2019. REF2019CT4495..
  2. TECNIS Eyhance IOL ICB00 – DfU INT – Z311058, Rev. 04, Dec. 2019. REF2020CT4318.

  3. DOF2018CT4015-Clinical investigation of the TECNIS Eyhance™ IOL, Model ICB00. Sep 2018 
  4. Holladay JT. International Intraocular Lens & Implant Registry 2003. J Cataract Refract Surg. 2003; 29:176-197. REF2016CT0151.

For healthcare professionals only. Please reference the Instructions for Use for a complete list of Indications and Important Safety Information and contact our specialists in case of any question. 
For outside the US use only. © Johnson & Johnson Surgical Vision, Inc. 2022 PP2022MLT4910