TECNIS™ 1-Piece Toric II IOL
Get a Grip on Visual Performance
With its squared and frosted haptic design the TECNIS™ Toric II platform delivers exceptional rotational stability.1
Excellent Visual Acuity
Leverage toric IOLs to reduce residual refractive cylinder and increase spectacle independence for
distance. 3,4
Ɨ Results are from study using TECNIS™ Toric IOL.
Long-Term Sustainability
Unlike another leading IOL, TECNIS™ IOL material is not associated with glistenings,5-9 which can
inhibit your patients’ vision. Glistenings cause light scatter, which can result in a reduction in image contrast. 6-10
Specifications
* Based on average pseudophakic human eye and ‘Holladay et al. A three-part system for refining intraocular lens power calculations. J Cataract Refract Surg. 1988;14(1):17-24. REF2014CT0092.
‡ Derived from clinical evaluation results of the TECNIS™ 1-Piece IOL Platform for optical biometry.
§ A-Constant theoretically derived for ultrasound biometry.
IOL INSERTION
Recommended insertion instruments:
UNFOLDER™ Platinum 1 Series Delivery System: Intuitive push-and-twist, screw-style insertion
designed to facilitate lens implantation.
REFERENCES:
1. DOF2021CT4019 – Clinical Investigation of Rotational Stability of the TECNIS™ Toric II IOL – From
Study NXGT-202-QROS. 20 Aug. 2021.
2. DOF2015OTH0006 – TECNIS™ and competitor toric IOL MTF data. 4 May 2015.
3. Black D. Efficacy of hydrophobic acrylic toric IOL to correct astigmatism in cataract patients. Presented at ASCRS 2015. REF2015CT0193.
4. Post-Approval Study of the TECNIS™ Toric IOL Extended Cylinder Range (ECR), Models ZCT450, ZCT525 and ZCT600. 30 August 2017. REF2018CT4111.
5. 150 – Data on File – SENSAR™ not associated with glistening – Literature analysis. May 2013. REF2014OTH0002.
6. Nagata M, et al. Clinical evaluation of the transparency of hydrophobic acrylic intraocular lens optics. J Cataract Refract Surg. 2010;36(12):2056-2060. REF2015CT0080.
7. Christiansen G, et al. Glistenings in the AcrySof® intraocular lens: Pilot study. J Cataract Refract Surg. 2001;27(5):728-733. REF2014MLT0005.
8. Colin J, et al. Incidence of glistenings with the latest generation of yellow-tinted hydrophobic acrylic intraocular lenses. J Cataract Refract Surg. 2012;38(7):1140-1146. REF2014MLT0006.
9. Gunenc U, et al. Effects on visual function of glistenings and folding marks in AcrySof® intraocular lenses. J Cataract Refract Surg. 2001;27(10):1611-1614. REF2014MLT0011.
10. Van der Mooren M, Franssen L, Piers P. Effects of glistenings in intraocular lenses. Biomed Opt Express. 2013;4(8):1294-1304. REF2014OTH0139.
11. TECNIS™ Toric II IOL, Model ZCU100-ZCU800 – DfU OUS – Z311613, Rev. A, 07/2020.
REF2021CT4064.
12. Holladay JT. International Intraocular Lens & Implants registry 2003. J Cataract Refract Surg.
2003;29:176-197.
REF2016CT0151.
For healthcare professionals only. Please reference the Instructions for Use for a complete list of
Indications and Important Safety Information and contact our specialists in case of any question.
©Johnson&Johnson and its affiliates 2024
For healthcare professionals only. Please reference the Instructions for Use for a complete list of Indications and Important Safety Information and contact our specialists in case of any question.
© Johnson & Johnson Surgical Vision, Inc. 2022. PP2022MLT4910